Dryer Cartridge, Removing And Installing, SHOWA/KEIHIN Condenser: Notes
WARNING: This page is about a different variant/trim than selected.
Special tools and workshop equipment required
- Commercially available pick-up tool
WARNING:
Danger due to refrigerant coming out under pressure.
Danger of frost bite to skin and other parts of the body.
- Evacuate the refrigerant and immediately open the refrigerant circuit afterward.
- If more than 10 minutes have elapsed since evacuating the refrigerant and the refrigerant circuit was not opened, evacuate the refrigerant again. Pressure in the refrigerant circuit is caused by evaporation.
NOTE:
Certain tools are required to discharge the refrigerant circuit. These work procedures may only be performed by trained personnel. Refer to Refrigerant Circuit (Refrigerant R134a Servicing, Refrigerant Circuit, Working with A/C Service Station) and Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .