LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2017 >> TT Quattro Base, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 19 (General, Technical Data (HVAC) [Coupe]) >> 00 General, Technical Data >> Repair Information >> Cooling Output, Checking >> Cooling Output, Checking, Vehicles With Automatic Climate Control System

Cooling Output, Checking, Vehicles With Automatic Climate Control System

WARNING: This page is about a different variant/trim than selected.

Refer to INFORMATION ON CHECKING COOLING OUTPUT AND TOOLS REQUIRED 

NOTE:

This Service Information only outlines the testing procedure. Perform the detailed test for this heating and A/C system function as described in the Guided Fault Finding using the Vehicle Diagnostic Tester in the"Guided Fault Finding"  function.

Procedure 

-- Measure the ambient temperature: It must be greater than 15 °C (59 °F).

-- Close the doors, hood, windows, sliding sunroof and rear lid.

-- Open all instrument panel vents and, if equipped, the vents in the rear center console.

-- Start the engine.

-- Adjust the following settings on the A/C system control heads:

GWWA00-11056Courtesy of AUDI OF AMERICA, LLC
NOTE:

This illustration shows the layout of the regulators -1, 2 and 3- and the buttons -4 and 5- on a LHD vehicle. The layout may be different on RHD vehicles.

The information in the regulators -1, 2 and 3- is only displayed when the ignition is switched on and goes out when the ignition is switched off.

-- "Read the measured values" using the Vehicle Diagnostic Tester in the"Guided Fault Finding"  function (for the Climatronic Control Module -J255-).

Checking

-- Read the activation of the A/C Compressor Regulator Valve -N280-.

-- Read the measured value for the Refrigerant Circuit Pressure Sensor -G805-.

Ambient Temperature in °C (°F) Displayed Pressure (Pressure in bar)
15 (59) 3.0
20 (68) 4.0
25 (77) 5.0
30 (86) 6.0
35 (95) 7.0
NOTE:

At absolute pressure, 0 bar corresponds to absolute vacuum. Normal ambient pressure equals approximately 1 bar absolute pressure and 0 bar pressure. On the scales of most pressure gauges, 0 bar pressure corresponds to an absolute pressure of one bar (can be seen from -1 mark below 0).

Pressure in refrigerant circuit is governed by the ambient temperature. Due to the heat given off by components (for example, the radiator), the pressure displayed with a warm engine will be slightly higher than that given for the respective ambient temperature.

If the displayed pressure in the refrigerant circuit is lower than in the table:

-- Check the signal for the Refrigerant Circuit Pressure Sensor -G805- using the Vehicle Diagnostic Tester in the"Guided Fault Finding"  function (for the Climatronic Control Module -J255-).

If no fault can be detected on the Refrigerant Circuit Pressure Sensor -G805-, there is too little refrigerant in the circuit.

-- The necessary work procedures may only be performed by qualified personnel. If this is not possible, bring the vehicle to a workshop that has the necessary tools and in which the work can be performed by qualified personnel. Refer to A/C SYSTEM, GENERAL INFORMATION or LAWS AND REGULATIONS . Bring the detected problems to the attention of the workshop.

If the displayed pressure in the refrigerant circuit is OK:

-- Adjust the following settings on the Climatronic Control Module -J255- control head:

GWWA00-11056Courtesy of AUDI OF AMERICA, LLC

-- "Read the measured values" using the Vehicle Diagnostic Tester in the"Guided Fault Finding"  function (for the Climatronic Control Module -J255-).

-- Check the information in the display fields:

If the displayed pressure does not change and the activation of the A/C compressor is OK:

-- Check once more if the A/C compressor is actually being driven and the A/C Compressor Regulator Valve -N280- is being activated.

If the current is actually flowing via the A/C Compressor Regulator Valve -N280- and the A/C compressor is being driven, then the fault is in the refrigerant circuit. It is possible that the A/C compressor regulation is not OK.

-- The necessary work procedures may only be performed by qualified personnel. If this is not possible, bring the vehicle to a workshop that has the necessary tools and in which the work can be performed by qualified personnel. Refer to A/C SYSTEM, GENERAL INFORMATION and LAWS AND REGULATIONS (the A/C compressor regulation may not be OK). Bring the detected problems to the attention of the workshop.

NOTE:

The Climatronic Control Module -J255- actuates the A/C Compressor Regulator Valve -N280- so that the air temperature reaches the specified value downstream of the evaporator (approximately 2 to 6 °C).

After starting the vehicle, a value greater than 0.55 A is displayed for the activation of the A/C Compressor Regulator Valve -N280- depending on the measured temperature, the engine speed and the electrical system voltage. As soon as the temperature measured by the Evaporator Vent Temperature Sensor -G263- nears the specified value, the activation is canceled and the A/C compressor output is reduced as a result.

Under certain operating conditions, moisture in the refrigerant circuit can lead to ice build-up on the A/C Compressor Regulator Valve -N280- and on the expansion valve. This ice build-up interferes with A/C compressor regulation. The evaporator is cooled too intensely and freezes. The freeze-up of the evaporator can be the cause for various customer complaints. Refer to LOCALIZING MALFUNCTION FOR ICE BUILD-UP ON EVAPORATOR .

If no or very little current is displayed in the measured values for the A/C Compressor Regulator Valve -N280- activation, check the activation of the A/C Compressor Regulator Valve -N280-. Use the Vehicle Diagnostic Tester in the"Guided Fault Finding"  function (for the Climatronic Control Module -J255-).

-- Press the Recirculation  button (in the regulator -4-) on the Front A/C Display Control Head 4 -E777-.

GWWA00-11056Courtesy of AUDI OF AMERICA, LLC

-- Set the engine speed to 2000 RPM (start of time measurement).

-- "Read the measured values" using the Vehicle Diagnostic Tester in the"Guided Fault Finding"  function (for the Climatronic Control Module -J255-).

-- Compare the displayed measured value for the Evaporator Vent Temperature Sensor -G263- with the values in the diagram.

Fig 1: Compare Displayed Value (From Evaporator Vent Temperature Sensor) With Values In Diagram
GWWA87-10572Courtesy of AUDI OF AMERICA, LLC

A -  Air temperature measured by the Evaporator Vent Temperature Sensor -G263-

B -  Ambient Temperature

C -  Permissible Tolerance Range

If the requested values are not reached:

-- Compare the measured values for the Left Vent Temperature Sensor -G150- (or the Right Vent Temperature Sensor -G151-) with the displayed measured value for the Evaporator Vent Temperature Sensor -G263-. Use the Vehicle Diagnostic Tester in the"Guided Fault Finding"  function (for the Climatronic Control Module -J255-).

-- Measure the temperature of the air coming out of the right instrument panel vent -2- with a thermometer (left vent on a RHD vehicle).

GWWA00-11054Courtesy of AUDI OF AMERICA, LLC
NOTE:

The designation and the component location of the vent temperature sensors (Left Vent Temperature Sensor -G150- and Right Vent Temperature Sensor -G151-) is different. The Left Vent Temperature Sensor -G150- is installed in the air duct to the left instrument panel vent -1- on LHD vehicles. The Right Vent Temperature Sensor -G151- is installed in the air duct to the right instrument panel vent -2- on RHD vehicles.

The temperature of the air coming out of the left -1- and right -2- instrument panel vents can also be measured with a thermometer.

If the measured values of the Evaporator Vent Temperature Sensor -G263- and Left Vent Temperature Sensor -G150- (or Right Vent Temperature Sensor -G151-) only slightly deviate from each other:

-- Perform the procedure for identifying malfunctions if there is a deviation from the specified value. Refer to DETERMINING MALFUNCTION IF DEVIATION FROM SPECIFIED VALUE .

If the measured value for the Evaporator Vent Temperature Sensor -G263- is greater than the measured value for the Left Vent Temperature Sensor -G150- (or Right Vent Temperature Sensor -G151-):

-- Make sure the Evaporator Vent Temperature Sensor -G263- is installed correctly (refer to Evaporator Vent Temperature Sensor -G263-, REMOVING AND INSTALLING ) and perform an electrical test for this sensor. Use the Vehicle Diagnostic Tester in the"Guided Fault Finding"  function (for the Climatronic Control Module -J255-).

NOTE:

The A/C system function can be recognized, for example, by the refrigerant pipe on the low pressure side (thick line) cooling off.

If the measured value for the Evaporator Vent Temperature Sensor -G263- and the A/C system cooling output is OK and there are no complaints, the cooling output test ends.

If the measured value for the Evaporator Vent Temperature Sensor -G263- (and the A/C system cooling output) is not OK:

-- Perform the procedure for identifying malfunctions if there is a deviation from the specified value (requested cooling output is not reached). Refer to DETERMINING MALFUNCTION IF DEVIATION FROM SPECIFIED VALUE .

If the measured value for the Evaporator Vent Temperature Sensor -G263- (and the A/C cooling output) is OK and there is a complaint regarding excessive or different vent temperatures for the heating and A/C system:

-- Check the activation of the temperature control doors in the heater and A/C unit. Refer to AIR DISTRIBUTION HOUSING, REMOVING AND INSTALLING and use the Vehicle Diagnostic Tester in the"Guided Fault Finding"  function (for the Climatronic Control Module -J255-).