Charge Air System, Checking For Leaks
Special tools and workshop equipment required
- Turbo System Tester Kit:VAG1687
- Turbo System Tester Kit - Adapter 10:VAG1687/10
Procedure
Depending on the model preliminary work may be required. Refer to CHARGE AIR SYSTEM, CHECKING FOR LEAKS .
-- Connect the :VAG1687/10 on the air duct pipe -1-.
-- Connect the :VAG1687 to the adapter.
Prepare the :VAG1687 as follows:
-- Completely remove the pressure regulating valve -2- and close the valves -3 and 4-.
- Pull the knob in order to rotate the pressure regulating valve -2-.
-- Connect the :VAG1687 to compressed air -1- with a commercially available intermediate piece.
-- Drain the water in the viewing glass via the water drain plug -6-.
-- Open the valve -3-.
-- Set the pressure to 0.2 bar (2.9 psi) using the pressure regulating valve -2-.
- Pressure must not exceed 0.2 bar (2.9 psi)!
-- Open the valve -4- and wait until the test circuit is filled. Regulate the pressure to 0.2 bar (2.9 psi) again if necessary.
-- Listen, feel and use commercially available leak detection spray or the :VAG1842 to check the charge air system for leaks. Refer to the Operating Instructions for handling.
TIP:
A small quantity of air dissipates via the valves in the engine. For this reason a pressure retention test is not possible.
- Release the pressure in the test circuit by pulling off the coupling before removing the adapter.
Additional procedures. Refer to CHARGE AIR SYSTEM, CHECKING FOR LEAKS .