Tightening Specifications, Tightening Sequence
Tighten the bolts -arrows- to 10 Nm in a diagonal sequence.
Tighten the bolts in three steps as follows:
| Step | Bolts | Tightening Specification |
| 1 | 5 and 6 | Install all the way in by hand |
| 2 | 6 | 10 Nm |
| 3 | 5 | 10 Nm |
Tighten the bolts -arrows- to 10 Nm.
- Install the crankcase ventilation connector -1- with new Orings into the oil separator cover.
* Installed position: the tab -2- must engage into the guide -arrow-.