Home >> Audi >> 2017 >> S7 Prestige >> Repair and Diagnosis >> Engine Mechanical >> Blowers, Superchargers & Turbochargers >> Fuel System (General Information) >> 20 Fuel Supply >> Fuel System EVAP Leak Test >> EVAP SYSTEM LEAK TEST, VEHICLES WITH Leak Detection Pump -V144- (LDP) >> EVAP System, Testing

EVAP System, Testing

-- Plug or clamp LDP inlet (filter side) using Hose Clamps Up to 25 mm Dia. :VAS3094  or equivalent.

-- Attach fuel cap adapter to filler neck (-arrow-) and test hose to adapter.

GWWUS20-A164Courtesy of AUDI OF AMERICA, LLC

-- Set control valve -2- from "Hold" to "Test".

GWWUS20-A160Courtesy of AUDI OF AMERICA, LLC

-- Increase the current pressure until it reaches 10 in. (25 mbar) H2 O.

-- Monitor the pressure gauge -3- and the flow meter -4-. Allow the flow rate to decrease. If pressure builds to 10 in. (25 mbar) H2 O, the fuel system is full.

NOTE:

Depending on the level of fuel in the tank, it may take up to three minutes to notice a visible decrease in flow rate.

-- After the pressure has stabilized, set control valve -2- to "Hold".

-- After five minutes, the pressure must not drop below 8 in. (20 mbar) H2 O.

If pressure drops below 8 in. of water in five minutes then find leak with the smoke tester, soapy water and/or isolating components by clamping them off individually.

If fuel system pressurization does not stabilize:

-- Verify all fuel system outlets have been sealed before continuing.

CAUTION:

Clamp only soft rubber lines when isolating a leak. To avoid risk of damage, never clamp hard plastic lines!

NOTE:

Any flow shown on flow meter indicates a leak.

If flow meter on tester registers flow near or above preset pressure:

-- Clamp off hose -arrow- leading from EVAP Canister Purge Regulator Valve 1 -N80- to intake manifold.

GWWUS20-A165Courtesy of AUDI OF AMERICA, LLC

If No Flow Is Present And The Pressure Drop Is Above 8 In. Of Water After Five Minutes: 

-- Replace EVAP Canister Purge Regulator Valve 1 -N80- and repeat test before continuing.

If Meter Indicates No Flow After Test: 

-- Perform a quality check and return vehicle to customer.

If Flow Continues, Proceed As Follows: 

-- Refer to METHOD 1: LOCATE LEAK WITH SMOKE GENERATOR .

-- Refer to METHOD 2: LOCATE LEAK WITH ULTRASONIC TESTER .