Preparation Work For Calibrating Driver Assistance Systems
Perform the following steps using "quick access" if one or more driver assistance systems on the vehicle will be calibrated (without a previous axle alignment):
- Before driving the vehicle onto the alignment stand, make sure there is enough space between the vehicle and the calibrating device. The distance between the calibrating device and the vehicle: 120 cm ± 2.5 cm.
- If there is not sufficient space, drive vehicle backward on alignment stand in order to be able to use the corresponding space.
- Check the DTC memory and correct any malfunctions before beginning the calibration.
- Vehicle accurately aligned, suspension bounced and rocked several times
- Make sure that the sliding plates and turn tables are not touching the end stop when checking the wheel alignment.
- Connect the battery charger. Refer to BATTERY .
- Position the front wheels so they are straight.
- Connect Vehicle Diagnostic Tester to the vehicle and guide the diagnostic cable through the open window.
- The vehicle exterior lamps are off.
- All the vehicle doors are closed.
- Using the screen, turn on the calibration on the wheel alignment computer.