Coolant Flushing And Filling Device:Vas531007, Preparing:
-- Fill the container >>1<< with at least 20 liters of distilled water.
-- Fill the container >>2<< with at least 20 liters of coolant (50:50 mixture ratio; approximately -36 °C (33 °F)).
-- Drain the containers >>3<< and >>4<<.
-- Connect the battery charger.
-- Remove the valve block from the connector coupling on the equipment trolley,
-- Connect the :VAS531007 to the battery.
Coolant Flushing and Filling Device:VAS531007 , Bleeding:
-- Connect the suction hose -A- to the reservoir >>1<< with distilled water.
-- Connect the drain hose -arrow- on the connector coupling -B- on the valve block.
-- Close the shut-off valves -A- and -B-.
TIP:
- Do not attach the valve block to the :VAG1274/8 The filling hose must first be bled.
-- Switch on the pump for the :VAS531007 .
-- Open the shut-off valve -A-.
-- Briefly open the shut-off valve -B- so that the filling hose is bled.
-- Close the shut-off valves -A- and -B- again.