Evaporative Emissions Tester: KLI9210, Self-Test
Always Perform System Self-Test Of Evaporative Emissions Tester:KLI9210 Prior To Use To Ensure That There Are No Leaks.
Refer To Evaporative Emissions Tester:KLI9210 service information For Specific Instructions.
-- Connect Vehicle Interface Hose To Self-Test Port -1-, Ensuring That Fitting Is Finger-Tight. Over-Tightening Will Damage Fitting.
-- Turn Control Valve -2- To Test.
Gauge -3- Should Read 14 ± 1 In . Of Water.
If Gauge Does Not Read 14 ± 1 In . Of Water:
-- Verify That Valve On Evap Tester Nitrogen Cylinder Is Open And That Cylinder Has Sufficient Pressure Before Continuing.
-- Turn Fine Adjust Regulator Knob (-Arrow-) Until Gauge Reads 14 In. Of Water; Tighten Lock Nut.
If Gauge Still Does Not Read Within Above Range, Contact K-Line Customer Service - Technical Support For Additional Instructions Before Continuing.
-- Check Flow Meter -4-.
Meter Must Indicate No Flow.
-- Turn Control Valve To Hold Position.
-- Check Gauge.
Gauge Must Hold Pressure.
If Gauge Leaks Down:
-- Verify That Vehicle Interface Hose Is Firmly Seated And Repeat Previous Six Steps Before Continuing.
If Gauge Continues To Leak Down:
-- Use Ultrasonic Tester To Locate And Repair Leak Before Continuing. Refer To METHOD 2: LOCATE LEAK WITH ULTRASONIC TESTER
If The Leak Cannot Be Located Or Repaired, Contact K-Line Customer Service - Technical Support.