Monitor - Id $35: Camshaft Adjustment Bank 1
WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2018 Audi A3 Quattro, 2017 Audi A3 Quattro, 2016 Audi A3 Quattro, 2016 Audi A3, and 2015 Audi A3 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
-- Connect the scan tool.
-- Start the engine and run at idle.
-- Select "Diagnostic Mode 06: Check / test the results of components that are not continuously monitored".
Select "Monitor - ID $35".
-- Select the desired "Test - ID".
-- Check specified values at idle.
| Test - ID | DTC | Component or System | Min. | Max. | Additional Information |
|---|---|---|---|---|---|
| $80 | P0011 | VVT Intake Camshaft Diagnosis, Target Position Not Reached, Target Error. | 0.0° CRK | 10.0° CRK | Refer to DTC P0011 in the DTC summary table. Engine Control Module --, 2017 MY => P0011 |
| $81 | P000A | VVT Intake Camshaft Diagnosis, Specified Position Reached Too Slowly, Slow Response. | 10.0° CRK | 655.35° CRK | Refer to DTC P000A in the DTC summary table. Engine Control Module --, 2017 MY => P000A |
| $82 | P0014 | VVT Exhaust Camshaft Diagnosis, Target Position Not Reached, Target Error. | 0.0° CRK | 10.0° CRK | Refer to DTC P0014 in the DTC summary table. Engine Control Module --, 2017 MY => P0014 |
| $83 | P000B | VVT Exhaust Camshaft Diagnosis, Specified Position Reached Too Slowly, Slow Response. | 3.5° CRK | 655.35° CRK | Refer to DTC P000B in the DTC summary table. Engine Control Module --, 2017 MY => P000B |
-- If any of the components or systems fail to meet the specified values, refer to Diagnostic "Mode 03: Interrogating Fault Memory" to check for stored DTC's or the corresponding diagnostic repair procedure DIAGNOSTIC MODE 03 - READ DTC MEMORY .
-- Switch the ignition off.