Test Procedure
WARNING: This page is about a different car, the 2018 Audi A3 Quattro, 2017 Audi A3 Quattro, 2016 Audi A3 Quattro, 2016 Audi A3, and 2015 Audi A3 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
| Step |
Procedure |
Result / Action to Take |
| 1 |
Activate Monitors:
- Perform the function test in Diagnostic Mode 06. Refer to appropriate Diagnostic Mode 06 - Read Test Results for Specific Diagnostic Functions, DIAGNOSTIC MODES 01 - 0A
.
- End diagnosis and switch the ignition off.
- If the specified values are exceeded:
|
- Check the exhaust system for leaks.
- If necessary, repair the leak(s) in the exhaust system.
- GO TO: Step 2.
|
| 2 |
O2 Sensor Monitoring:
|
- Generate readiness code. Refer to READINESS CODE
.
- If no leaks are found in the exhaust system:
- Replace the catalytic converter with front exhaust pipe. Refer to appropriate Service Information.
- GO TO: Step 3.
|
| 3 |
- Final procedure:
- Perform a road test to verify repair.
|
|