Overview - Charge Air Hose Connections
- The hose connections as well as air duct pipes and hoses must be free of oil and grease before installing.
- Secure all hose connections with hose clamps that match the ones used in series production. Refer to the Electronic Parts Information (ETKA).
- In order to be able to securely mount the air duct hoses on their connections, spray the bolts on the previously used screw-type clamps with rust remover before installing.
Tightening Specification For Charge Air Hose Connections
- Hose clamp -a- = 12 mm wide: 5.5 Nm
- Hose clamp -b- = 9 mm wide: 3.4 Nm