Battery, Charging With Battery Charger VAS 5095A: Procedure
-- Turn off the ignition and all electrical consumers and remove the ignition key.
-- Check the battery type setting on the Battery Type switch, refer to BATTERY CHARGER VAS 5095A DEVICE DESCRIPTION . The Battery Type switch must be set to 2.4 V/C (Volts/Cell).
-- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.
-- Connect the black charge terminal (-) to the negative terminal of the Battery -A- /negative connector.
-- Switch on the Battery Charger VAS 5095A, refer to BATTERY CHARGER VAS 5095A DEVICE DESCRIPTION .
Charge current displays Figure -2- and -3- light up yellow. The Battery -A- is partially charged (approximately 90%) when only the yellow LED -3- is on.
If the green LED Figure -4- is also on, then the Battery Charger VAS 5095A has switched to maintenance charging. The Battery -A- is charged.
-- Switch off the Battery Charger VAS 5095A, refer to BATTERY CHARGER VAS 5095A DEVICE DESCRIPTION .
-- Remove the charging clamps from the battery terminals.