LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2017 >> A7 Quattro Competition >> Repair and Diagnosis >> External Pages >> Different car >> Section 49 (Refrigerant R134A Servicing (Refrigerant Circuit)) >> 87 Air Conditioning >> Refrigerant Circuit >> Refrigerant Circuit, Determining Leaks >> Finding Leaks Via Vacuum Test Using A/C Service Station Or Nitrogen Pressure Testing

Finding Leaks Via Vacuum Test Using A/C Service Station Or Nitrogen Pressure Testing

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2015 Audi S7, 2015 Audi RS 7, 2015 Audi A7 Quattro, 2014 Audi S7, and 2014 Audi RS 7. However, it is still accessible from the selected car via links, so may be relevant.

Vehicles with a High Voltage System (Hybrid Vehicles) 

Read and follow all of the supplemental warnings for all work performed on vehicles with the high voltage system. Refer to WARNINGS WHEN WORKING ON VEHICLES WITH HIGH VOLTAGE SYSTEM  .

All vehicles 

-- Turn off the ignition.

NOTE:

Small leaks (less than 100 g of refrigerant loss per year) are not often detected with the vacuum test or with the nitrogen pressure test. The incoming air and the amount of nitrogen flowing out is too small to be able to locate the faulty location based on noise.

Leaks on the refrigerant circuit that are greater than 100 g of refrigerant loss each year are also not always detectable with the vacuum test or with the nitrogen pressure test, depending on the ambient conditions (ambient noise, leak location etc.). The incoming air and the quantity of nitrogen flowing out is currently too small to detect any noise and locate the faulty location.

Larger leaks on the refrigerant circuit (for example, an impact from a rock on the condenser, refrigerant loss greater than 100 g per year) can be detected, for example by noise, using the vacuum test or the nitrogen pressure test. Refer to REFRIGERANT CIRCUIT, DISCHARGING WITH SERVICE STATION .