Home >> Audi >> 2017 >> A7 Quattro Competition >> Repair and Diagnosis >> External Pages >> Different car >> Section 49 (Refrigerant R134A Servicing (Refrigerant Circuit)) >> 87 Air Conditioning >> Refrigerant Circuit General Information >> Refrigerant Circuit Components Allocation, High And Low Pressure Sides >> Pressure Relief Valve

Pressure Relief Valve

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2015 Audi S7, 2015 Audi RS 7, 2015 Audi A7 Quattro, 2014 Audi S7, and 2014 Audi RS 7. However, it is still accessible from the selected car via links, so may be relevant.

The pressure relief valve is installed on the A/C compressor or receiver/dryer.

Fig 1: Identifying A/C Refrigerant System Pressure Relief Valve
GWWV87-1456Courtesy of AUDI OF AMERICA, LLC

At a pressure of approximately 38 bar positive pressure, valve opens and closes again once pressure has dissipated (approximately 30 bar).

Refrigerant does not escape completely.

NOTE:

Depending on the version, a transparent plastic disc -B- may be installed on the pressure relief valve -A-, which breaks off as soon as the valve is activated.

Fig 2: Identifying Transparent Plastic Disc -B- And Pressure Relief Valve -A-
GWWA87-11386Courtesy of AUDI OF AMERICA, LLC

Depending on the pressure relief valve version -A-, an additional cover -C- can be slid onto the pressure relief valve -A-. If the pressure in the refrigerant circuit does rise above the pressure relief valve -A- opening pressure and the valve opens, the refrigerant does not escape in one direction, but rather it is distributed through the openings -D- under the cover -C-.