LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2017 >> A7 Quattro Competition >> Repair and Diagnosis >> External Pages >> Different car >> Section 49 (Refrigerant R134A Servicing (Refrigerant Circuit)) >> 87 Air Conditioning >> A/C System, General Information >> After Charging A/C System

After Charging A/C System

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2015 Audi S7, 2015 Audi RS 7, 2015 Audi A7 Quattro, 2014 Audi S7, and 2014 Audi RS 7. However, it is still accessible from the selected car via links, so may be relevant.

Mechanically Driven A/C Compressor 

After installing the A/C Compressor to the engine (before positioning the belt or installing the driveshaft) Refer to A/C SYSTEM, OPERATING AFTER CHARGING  and A/C Compressor Regulator ValveN280, Removing and Installing .

-- Turn the A/C compressor by hand via the clutch plate or belt pulley on the A/C clutch approximately 10 turns.

After charging. Refer to A/C SYSTEM, OPERATING AFTER CHARGING .

-- Start the engine with the A/C turned off (A/C Clutch -N25- and A/C Compressor Regulator Valve -N280- are not actuated).

-- Following engine idling speed stabilization, switch on A/C compressor and run it for at least 10 minutes at idling speed with maximum cooling output.

Electrically Driven A/C Compressor 

-- First start the electrically driven A/C compressor after filling the refrigerant circuit via the "Compressor Cut-In" function from the basic setting. Refer to A/C SYSTEM, OPERATING AFTER CHARGING  and Vehicle Diagnostic Tester in the "Guided Fault Finding" Function for the A/C System and the Battery Regulation.