Coolant Mixture Ratio
- Coolant (40%) and water (60%) for freeze protection down to -25 °C (-13 °F)
- Coolant (50%) and water (50%) for freeze protection down to -36 °C (-32.8 °F)
- Coolant .
Procedure
-- Connect the coolant hose and connector coupling -arrow- to the right rear, refer to Figure.
-- Close the drain plug -1-.
-- Attach the coolant hose and connector coupling -2- to the bottom of the radiator, refer to Figure.
-- Connect the coolant hose and clamp -arrow- to the left front coolant pipe.
-- Fill the coolant reservoir on the Cooling System Charge Kit VAS 6096 with at least twelve liters of premixed coolant with the proper mixture ratio:
-- Install the Cooling System Tester - Adapter VAG 1274/8 on the coolant expansion tank.
-- Attach the Cooling System Charge Kit VAS 6096 on the Cooling System Tester - Adapter VAG 1274/8.
-- Place the air outlet hose -1- in a small container -2-.
A small amount of coolant which should be collected is drawn off with the discharged air.
-- Close valves -A and B- by turning lever at a right angle to direction of flow.
-- Connect the hose -3- to compressed air.
- Pressure: 6 to 10 bar (87 to 145 psi) positive pressure.
-- Open valve -B- by turning level in direction of flow.
- The suction jet pump generates pressure in the coolant system; indicator on display instrument must move into green area.
-- Briefly open valve -A- by turning lever in direction of flow so that hose on the Cooling System Charge Kit VAS 6096 coolant reservoir fills with coolant.
-- Close valve -A- again.
-- Leave valve -B- open another two minutes.
- More pressure is generated in the coolant system by the suction jet pump; indicator on display instrument must stay in green area.
-- Close valve -B-.
- Needle in the display instrument must remain in the green region, then the sufficient vacuum in the cooling system is obtained for the upcoming filling.
If needle stands below the green area, repeat procedure.
If pressure falls, check coolant system for leaks.
-- Remove pressurized air hose.
-- Open valve -A-.
- Coolant is extracted from the Cooling System Charge Kit VAS 6096 coolant reservoir by pressure in the coolant system and the system is filled.
-- Remove the Cooling System Charge Kit VAS 6096 from the Cooling System Tester - Adapter VAG 1274/8 on coolant expansion tank.
-- Connect the Cooling System Tester - Adapter VAG 1274/10 to the Cooling System Tester - Adapter VAG 1274/8.
-- Fill the coolant until the coolant system tester tube is full. Fill again during the bleeding procedure if necessary.
-- Remove the engine cover, refer to ENGINE COVER, REMOVING AND INSTALLING .
-- Remove the plenum chamber cover, refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .
Vehicles with A Turbocharger
-- Open the bleeder screw -arrow- on the front coolant line until the coolant starts to come out.
-- Close the bleeder screw.
Continuation for All Vehicles
-- Disconnect the heat exchanger coolant hose and pull it back until coolant starts to drain out of the bleeder hole -arrow- in the coolant hose.
-- Slide the coolant hose onto the connection and secure with a clamp.
-- If the vehicle has a parking heater, switch it on for about 30 seconds.
-- Close the cap -arrow- on the coolant reservoir until it locks.
-- Start the engine.
| Duration | Engine RPM | Conditions |
|---|---|---|
| 3 Minutes | 2000 RPM |
|
| Until both large coolant hoses on the radiator are warm | Idle |
|
| 2 Minutes | 2000 RPM |
|
-- Turn off engine and allow it to cool off.
-- Install the noise insulations, refer to NOISE INSULATION, REMOVING AND INSTALLING .