Home >> Audi >> 2017 >> A7 Quattro Competition >> Repair and Diagnosis >> External Pages >> Different car >> Section 112 (Engine Lubrication System (Service Information - 4.0L - CEUC, CRDB, CTGE, CWUB, CWUC)) >> 17 Lubrication >> Oil Circuit >> Cover In The Inner-V, Removing And Installing >> Removing

Cover In The Inner-V, Removing And Installing: Removing

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2018 Audi S7, 2018 Audi RS 7, 2017 Audi S7, 2017 Audi RS 7, and 2016 Audi S7. However, it is still accessible from the selected car via links, so may be relevant.

-- Remove the housing for the charge air cooler. Refer to CHARGE AIR COOLER HOUSING, REMOVING AND INSTALLING .

-- Disconnect the connector -3-.

GWWA17-10732Courtesy of AUDI OF AMERICA, LLC

-- Remove the bolts -1- and then remove the hose lines.

-- Loosen the hose clamps to remove the oil return hose -2-.

-- Remove the bolts in the following sequence -11 to 1-, and then remove the cover in the inner-V.

Fig 1: Cover Bolts Tightening Sequence
GWWA17-11072Courtesy of AUDI OF AMERICA, LLC

-- Disconnect the connector -arrow- and free up the wire.