Pinpoint Test G : B1B71:11 Or B1B71:15
WARNING: This page is about a different car, the 2017 Lincoln Navigator and 2017 Ford Expedition. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may cause damage to the connector.
- G1 CHECK THE EVAPORATOR TEMPERATURE SENSOR RESISTANCE
- Ignition OFF.
- Disconnect: Evaporator temperature sensor C296.
- Measure:
Positive Lead Measurement / Action Negative Lead
C296-1 component side
C296-2 component sideAmbient Temperature Resistance (Ohms) -40 °C (-40 °F) 1, 005, 00-1, 104, 000 -20 °C (-4 °F) 287, 811-307, 800 0 °C (32 °F) 96, 890-101, 300 20 °C (68 °F) 37, 080-38, 000 25 °C (77 °F) 29, 700-30, 300 30 °C (86 °F) 23, 840-24, 430 35 °C (95 °F) 19, 260-19, 820 40 °C (104 °F) 15, 660-16, 180 60 °C (140 °F) 7, 239-7, 594 100 °C (212 °F) 1, 943-2, 091
Is the resistance within the specified values for the temperatures?
Yes GO to G2. No INSTALL a new evaporator temperature sensor. REFER to Climate Control . - G2 CHECK THE HVAC CONTROL MODULE OUTPUT VOLTAGE
- Ignition ON.
- Select PANEL on the HVAC controls.
Is the voltage between 4.7 and 5.1 volts?
Yes GO to G7. No GO to G3. - G3 CHECK THE EVAPORATOR TEMPERATURE SENSOR CIRCUITS FOR A SHORT TO VOLTAGE
- Ignition OFF.
- Disconnect: HVAC control module - EMTC C2357A.
- Disconnect: HVAC control module - EATC C228A.
- Ignition ON.
Is any voltage present?
Yes REPAIR the circuit in question. No GO to G4. - G4 CHECK THE EVAPORATOR TEMPERATURE SENSOR CIRCUITS FOR A SHORT TO GROUND
- Ignition OFF.
Are the resistances greater than 10, 000 ohms?
Yes GO to G5. No REPAIR the circuit in question. - G5 CHECK THE EVAPORATOR TEMPERATURE SENSOR CIRCUITS FOR AN OPEN
- For EATC vehicles, measure:
Positive Lead Measurement / Action Negative Lead C296-1 C228A-19 C296-2 C228A-23
- For EMTC vehicles, measure:
Positive Lead Measurement / Action Negative Lead C296-1 C2357A-6 C296-2 C2357A-10
Are the resistances less than 3 ohms?
Yes GO to G6. No REPAIR the circuit in question. - For EATC vehicles, measure:
- G6 CHECK THE EVAPORATOR TEMPERATURE SENSOR CIRCUITS FOR A SHORT TOGETHER
Is the resistance greater than 10, 000 ohms?
Yes GO to G7. No REPAIR the circuits. - G7 CHECK FOR CORRECT HVAC CONTROL MODULE OPERATION
- Disconnect and inspect all HVAC control module connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect all HVAC control module connectors. Make sure they seat and latch correctly.
- Operate the system and verify the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable TSBs. If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no TSB addresses this concern, INSTALL a new HVAC control module. REFER to Climate Control . No The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. ADDRESS the root cause of any connector or pin issues.