LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2017 >> A6 Premium Plus >> Repair and Diagnosis >> Engine Mechanical >> Blowers, Superchargers & Turbochargers >> Turbocharger System (Service Information - CYNB - 1 Of 2) >> Turbocharger, Supercharger >> Charge Air System >> Charge Air System, Checking For Leaks

Charge Air System, Checking For Leaks

Special Tools And Workshop Equipment Required 

Required Preliminary Work. Refer to CHARGE AIR SYSTEM, CHECKING FOR LEAKS [CLAB, CLAA, CDUC, CGQB, CKVB, CKVC, CDUD, CPNB, CTCB, CTCC, CVUA, CVUB ENGINES] and/or CHARGE AIR SYSTEM, CHECKING FOR LEAKS [CYNB ENGINES] .

-- Follow the guidelines for clean working conditions. Refer to GUIDELINES FOR CLEAN WORKING CONDITIONS .

Prepare the :VAG1687  as follows:

GWWV21-0168Courtesy of AUDI OF AMERICA, LLC

-- Completely remove the pressure regulating valve -2- and close the valves -3 and 4-.

-- Connect the :VAG1687  to compressed air -1- with a commercially available intermediate piece.

-- Drain the water in the viewing glass via the water drain plug -6-.

-- Open the valve -3-.

CAUTION:

- Never Set The Test Pressure Specified.

-- Set the pressure to 0.2 bar (2.9 psi) using the pressure control valve -2-.

-- Open the valve -4- and wait until the test circuit is filled. Regulate the pressure to 0.2 bar (2.9 psi) again if necessary.

-- Listen, feel and use commercially available leak detection spray or the :VAG1842S  to check the charge air system for leaks. Refer to the Owner's Manual for information on using the :VAG1842S  .

TIP: 

A Small Quantity Of Air Dissipates Via The Valves In The Engine. For This Reason A Pressure Retention Test Is Not Possible.

ASSEMBLING 

-- Release the pressure in the test circuit by removing the hose coupling before removing the adapter.

Additional Procedures. Refer to CHARGE AIR SYSTEM, CHECKING FOR LEAKS [CLAB, CLAA, CDUC, CGQB, CKVB, CKVC, CDUD, CPNB, CTCB, CTCC, CVUA, CVUB ENGINES] and/or CHARGE AIR SYSTEM, CHECKING FOR LEAKS [CYNB ENGINES] .