Front Convertible Top Seal, Removing And Installing: Installing
Install in reverse order of removal and Note The Following:
-- Install the convertible top seal according the marking made during removal.
-- Mark the installation position of the Butyl cord -1- and the Butyl tape -2- on the convertible top seal -3- for reinstallation.
REPLACE
-- REPLACE the Butyl Sealing Cord: AKL 450 005 05 -1- and Butyl tape -2- and after the removal install according the marking made during removal.