Home >> Audi >> 2017 >> A3 Premium, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 9 (General, Technical Data (HVAC) -- (A3 Sedan)) >> 00 General, Technical Data >> Repair Information >> Heating Output, Checking >> Temperature Door Actuation, Checking >> if The Target Values Are Not Reached, Check The Following:

if The Target Values Are Not Reached, Check The Following:

WARNING: This page is about a different variant/trim than selected.
NOTE:

For vehicles with an After-Run Coolant Pump -V51- / Heater Support Pump -V488- (different designations, depending on the engine), bring the engine RPM to approximately 2000 RPM and repeat the test if necessary. If the air temperature goes above 55 °C (131 °F) when repeating the test at a higher engine speed, this indicates that there is too little coolant flowing through the heater core for the heater. Cause: The delivery rate of the engine coolant pump is too low while idling or the incorporation of the heater core for the heater into the coolant circuit is not according to the specification. Refer to COOLING SYSTEM/COOLANT [CRUA, DEJA] / COOLANT SYSTEM/COOLANT [CNSB, CNTC] (Connection Diagram for Coolant Hoses).

If too little warmed up coolant flows through the heater core for the heater, the required heat output is not reached.

-- Set the highest possible temperature for the front passenger side.

GWWA87-11326Courtesy of AUDI OF AMERICA, LLC

-- "Read measured values" for the Left Vent Temperature Sensor -G150- /Right Vent Temperature Sensor -G151- /Footwell Vent Temperature Sensor -G192-.

Target values with an engine temperature of about 90 °C (194 °F):

If the target values are not reached, check the components as described above. Refer to if The Target Values Are Not Reached, Check The Following: .

-- Set the lowest possible temperature for the driver and front passenger side.

GWWA87-11326Courtesy of AUDI OF AMERICA, LLC

-- "Read measure values" for the Left Vent Temperature Sensor -G150- /Right Vent Temperature Sensor -G151- /Footwell Vent Temperature Sensor -G192- and Evaporator Vent Temperature Sensor -G263-.

-- Compare the Left Vent Temperature Sensor -G150- /Right Vent Temperature Sensor -G151- /Footwell Vent Temperature Sensor -G192- measured values with the measured value for the Evaporator Vent Temperature Sensor -G263-.

Specified Values:

if The Target Values Are Not Reached, Check The Following: