Overview - Air Routing And Air Distribution In Passenger Compartment: Notes
WARNING: This page is about a different variant/trim than selected.
NOTE:
A head area heater is installed as optional equipment for the A3 Cabrio. On vehicles with a head area heater there is an additional vent installed in the seat and in the A/C control head the Climatronic Control Module -J255- there are additional buttons to switch on and off the head area heater. Additional information. Refer to HEAD AREA HEATER .
Air Distribution Housing, Front Air Guides
- Bolt
- 1.5 Nm
- Left Footwell Vent Air Guide - Driver Side
- Removing and installing. Refer to DRIVER SIDE FOOTWELL VENT .
- Air Guide
- To the defroster vents
- Removing and installing. Refer to DEFROSTER VENT AIR DUCT .
- Left Vent Temperature Sensor -G150-
- For equipment versions with Automatic climate control
- Improperly installed vent temperature sensors cause flow-generated noise
- Removing and installing. Refer to LEFT/RIGHT VENT TEMPERATURE SENSOR -G150- / -G151-, REMOVING AND INSTALLING .
- Plug for Left Vent
- For equipment versions with heater or manually regulated A/C system
- A loose or missing sealing plug causes flow-generated noise.
- Left Instrument Panel Vent
- To remove and install. Refer to OVERVIEW - INSTRUMENT PANEL / INSTRUMENT PANEL VENT, REMOVING AND INSTALLING .
- Left Center Instrument Panel Vent
- To remove and install. Refer to OVERVIEW - INSTRUMENT PANEL / INSTRUMENT PANEL VENT, REMOVING AND INSTALLING .
- Left Defroster Vent
- Removing and installing. Refer to SIDE DEFROSTER VENT .
- Center Defroster Vent
- Removing and installing. Refer to FRONT CENTER VENTS .
- Center Speaker Trim
- Right Defroster Vent
- Removing and installing. Refer to SIDE DEFROSTER VENT .
- Right Instrument Panel Vent
- To remove and install. Refer to OVERVIEW - INSTRUMENT PANEL / INSTRUMENT PANEL VENT, REMOVING AND INSTALLING .
- Right Vent Temperature Sensor -G151-
- For equipment versions with Automatic climate control
- Improperly installed vent temperature sensors cause flow-generated noise
- Removing and installing. Refer to LEFT/RIGHT VENT TEMPERATURE SENSOR -G150- / -G151-, REMOVING AND INSTALLING .
- Plug for Right Vent
- For equipment versions with heater or manually regulated A/C system
- A loose or missing sealing plug causes flow-generated noise.
- Right Center Instrument Panel Vent
- To remove and install. Refer to OVERVIEW - INSTRUMENT PANEL / INSTRUMENT PANEL VENT, REMOVING AND INSTALLING .
- Center Instrument Panel Air Guide Vent
- Removing and installing. Refer to CENTER INSTRUMENT PANEL VENT AIR GUIDE .
- Sealing Plugs
- For equipment versions without glove compartment cooling
- Secure loose plugs with a spring-type clamp. Refer to SEALING PLUG FOR GLOVE COMPARTMENT COOLING NOTE:
Glove compartment cooling insert open.
Depending on the version, the connection can also be directly sealed on the heater and A/C unit.
- Bolt
- 1.5 Nm
- Right Footwell Vent Air Guide - Front Passenger Side
- Removing and installing. Refer to FRONT PASSENGER SIDE FOOTWELL VENT .
- Heater and A/C Unit
- There are different versions.
- Removing and installing. Refer to HEATER AND A/C UNIT, REMOVING AND INSTALLING .