LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2017 >> A3 Premium, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 50 (Air Conditioning (Front Heater & A/C Unit) -- (Sedan)) >> 87 Air Conditioning >> Actuators >> RECIRCULATION Door Motor -V113-, Removing And Installing >> Installing

RECIRCULATION Door Motor -V113-, Removing And Installing: Installing

WARNING: This page is about a different variant/trim than selected.

Install In Reverse Order Of Removal. Note The Following: 

NOTE:

Check the function of the doors and linkage before installing.

Check if the lever and shafts are seated correctly in the mounts.

-- The fresh-air door must be set to "opened".

NOTE:

If the actuating shaft of the actuator is not set to "fresh-air mode" stop, turn the mount in the actuator. See notes. Refer to ACTUATOR .

-- Mount the actuator to the air intake housing so that the actuating shaft engages into the mount.

NOTE:

If the bolts cannot be installed, the actuator does not sit completely on the housing.

-- Install the wiring harness so that it cannot come in contact with any moving parts (for example, the lever on the actuator).

-- To check the actuator function, connect the adapter cable (refer to ACTUATOR ) or connect the actuator terminals "5" and "6" to a 12 V battery via a 5A fuse using a cable from the :VAG1594D  .

NOTE:

Turn the actuator so far until it has reached a favorable position for installation. The direction of rotation can be reversed by switching the positive and negative.

-- Check the DTC memory and erase any displayed entries, then perform the "basic setting". Use the :Vehicle Diagnostic Tester  in the "Guided Fault Finding"  function.

-- Check the heater and A/C unit function.