Service Connection On Low And High Pressure Side, Removing And Installing: Removing
-- Remove the sealing caps (with seal) -1 or 2-.
-- Discharge the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, DISCHARGING WITH A/C SERVICE STATION (R134a) / REFRIGERANT CIRCUIT, EVACUATING WITH A/C SERVICE STATION (R134a) / REFRIGERANT CIRCUIT, CHARGING WITH A/C SERVICE STATION (R134a) (Refrigerant R134a Servicing, Refrigerant Circuit, Working with A/C Service Station) or REFRIGERANT CIRCUIT, DISCHARGING (R1234yf) / REFRIGERANT CIRCUIT, EVACUATING (R1234yf) / REFRIGERANT CIRCUIT, CHARGING (R1234yf) .
Danger Due To Refrigerant Coming Out Under Pressure.
Danger of frost bite to skin and other parts of the body.
- Evacuate the refrigerant and immediately open the refrigerant circuit afterward.
- If more than 10 minutes have elapsed since evacuating the refrigerant and the refrigerant circuit was not opened, evacuate the refrigerant again. Pressure in the refrigerant circuit is caused by evaporation.
-- Remove the service connection -3- using the :T10364 and a suitable adapter.
Additional information about the service connection. Refer to SERVICE CONNECTION DIFFERENCES, DEPENDING ON REFRIGERANT (R134A OR R1234YF) , A/C SYSTEM, GENERAL INFORMATION (R134a) or REFRIGERANT CIRCUIT (R1234yf) / GENERAL DESCRIPTION - REFRIGERANT CIRCUIT COMPONENTS (R1234YF) .