LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2017 >> A3 Premium, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 11 (Charging System (Battery, Starter, Generator) & Cruise Control -- (A3 Sedan) (Battery & Charging)) >> 27 Starter, Generator And Cruise Control >> Battery, Charging >> Battery Charger : Vas5903 >> Refresh Charging With Battery Charger : Vas5903 >> Procedure

Refresh Charging With Battery Charger : Vas5903: Procedure

WARNING: This page is about a different variant/trim than selected.

-- Turn off the ignition and all electrical consumers and remove the ignition key.

-- Connect the :VAS5903  to the power supply. The last selected operation mode is shown on the display. Refer to BATTERY CHARGER .

-- Set the battery type with the INFO  button.

GWWN27-10611Courtesy of AUDI OF AMERICA, LLC

The symbol -1- for "refresh - charging wet batteries" or the symbol -2- for "refresh - charging of Gel/Absorbent Glass Mat (AGM) batteries" is indicated in the display.

-- Set the battery capacity (Ah) on the Battery -A- to be charged with the corresponding ↑  button or ↓  button.

-- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.

NOTE:

On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.

-- Connect the black charge terminal (-) to the negative terminal of the Battery -A- /negative connector.

The :VAS5900  recognizes the nominal voltage of the connected Battery -A- (6 V/12 V/24 V) and begins the charging process automatically.

The :VAS5900  begins the "final charging" when the charge level is approximately 80 to 85 % of the battery voltage. The fourth bar is indicated on the display -1-. The Battery -A- is now ready to be used.

GWWN27-10170Courtesy of AUDI OF AMERICA, LLC
NOTE:

A successful "Refresh charge" depends on the degree of sulfation on the Battery -A-.

Possible Malfunctions and How They Are Handled 

  1. Displayed voltage does not match the nominal voltage:

    -- Hold down the ↑  button or ↓  button until the charging process begins.

  2. Displayed battery voltage does not match rated voltage - charging process has already begun:

    -- Press the START/STOP  button two times.

    -- Hold down the ↑  button or ↓  button until the charging process begins.

  3. The charger does not recognize a Battery -A-, when the battery voltage is less than 2 V:

    The display remains unchanged.

    The set operating mode and Ampere-hours (Ah) are displayed.

Battery -A- charging, ending 

-- Press the START/STOP  -button.

-- Remove the charging clamps from the battery terminals.

-- Disconnect the :VAS5903  from the power.