LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2017 >> A3 Premium, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 92 (Controls, Housing 6-Speed Dual-Clutch Transmission 0D9 (1 Of 2)) >> 34 Controls, Housing >> MECHATRONIC >> Overview - MECHATRONIC

Overview - MECHATRONIC

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2017 Audi S3, 2017 Audi A3 Quattro, 2016 Audi S3, 2016 Audi A3 Quattro, and 2016 Audi A3. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Exploded View Of Mechatronic
GWWA34-11158Courtesy of AUDI OF AMERICA, LLC
  1. Drain and Check Plug
    • 45 Nm
  2. Seal
    • Always replace after removing
  3. Overflow Pipe
    • 3 Nm
  4. Bolt
    • Tightening specification and sequence. Refer to Fig 3
    • Always replace after removing
    • Quantity: 10
  5. Oil Pan
  6. Bolt
    • Tightening specification and sequence. Refer to Fig 2
    • Always replace after removing
    • Quantity: 5
  7. Gasket
    • Always replace after removing
  8. DSG Transmission Mechatronic -J743-
  9. Bleed Cap
    • Placed on bleed pipe
  10. Bleed Pipe
    • Pressed into transmission
    • Always replace after removing
  11. Transmission Oil Pump
  12. Transmission Oil Pump Cover
  13. Bolt
    • Tightening specification and sequence. Refer to Fig 4
    • Always replace after removing
    • Quantity: 4
  14. Bolt
    • Tightening specification and sequence. Refer to Fig 5
    • Always replace after removing
    • Quantity: 4
    • Different versions. For the correct allocation. Refer to the Parts Information.
  15. Gasket
    • Always replace after removing

Tightening Specification and Tightening Sequence of the Oil Pan A.

Fig 2: Exploded View Of Transmission Oil Pan
GWWA37-0672Courtesy of AUDI OF AMERICA, LLC

-- Tighten the screws -arrows- diagonally in steps to 16 Nm.

Tightening Specification and Sequence DSG Transmission Mechatronic J743.

Fig 3: DSG Transmission Mechatronic Bolts Tightening Sequence (-J743-)
GWWA34-11104Courtesy of AUDI OF AMERICA, LLC
NOTE:

Replace the bolts that were tightened with an additional turn.

-- Tighten the bolts in steps in the sequence shown:

Step Bolts Tightening Specification/Additional Turn
1. -1 to 10- 5 Nm
2. -1 to 10- Tighten 90° further

Tightening Specification and Sequence of the Transmission Oil Pump Cover A.

Fig 4: Identifying Cap For Transmission Oil Pump And Fasteners
GWWA37-0670Courtesy of AUDI OF AMERICA, LLC

-- Tighten the screws -arrows- diagonally in steps to 8 Nm.

NOTE:

Replace the bolts.

Tightening Specification and Sequence of the Transmission Fluid Pump.

Fig 5: Bolts With Torque Specifications
GWWN34-10842Courtesy of AUDI OF AMERICA, LLC
NOTE:

Replace the bolts that were tightened with an additional turn.

-- Tighten the bolts in steps as follows:

Step Bolts Tightening Specification/Additional Turn
1. Upper countersink bolt 8 Nm with Wrench - Pump/Injector Long Reach: T10054 
2. Flat head screws 8 Nm
3. Flat head screws Tighten 90° further