Home >> Audi >> 2017 >> A3 Premium, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 38 (Fuel Supply System -- (A3 Sedan)) >> 20 Fuel Supply System >> Fuel Pump >> Transfer Fuel Pump -G6-, Checking >> Transfer Fuel Pump -G6-, Checking, Vehicles With 5-Cylinder Engine >> Notes

Transfer Fuel Pump -G6-, Checking, Vehicles With 5-Cylinder Engine: Notes

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2017 Audi S3, 2017 Audi RS 3, 2017 Audi A3 Quattro, 2016 Audi S3, and 2016 Audi A3 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

Special Tools And Workshop Equipment Required 

- Check Fuel Delivery Rate

Fig 1: Identifying Cap -2-
GWWA20-11453Courtesy of AUDI OF AMERICA, LLC

-- Observe all test conditions. Refer to TEST CONDITIONS .

-- Release and open the fuel filler door.

-- Clean the area around the fuel filler neck.

-- Remove the cap -2- for the fuel filler -1-.

NOTE:

Ignore -3-.

GWWA20-11505Courtesy of AUDI OF AMERICA, LLC
WARNING:

Risk of injury due to the fuel being under high pressure.

  • To reduce the pressure in the fuel system, lay clean cloths around the connection point and carefully loosen the connection point.

-- Disconnect the fuel line -1-. Disconnect the connector couplings. Refer to CONNECTOR COUPLINGS, DISCONNECTING .

NOTE:

Ignore -2-.

-- Connect the :VAS6550  to the fuel supply line with the :VAS6550/2  .

GWWA20-11506Courtesy of AUDI OF AMERICA, LLC

-- Connect the :VAS6550/4  and hold the hose in a fuel-resistant measuring container.

-- Switch on the :VAS6550  -1- by pressing the On/Off  button.

Fig 2: Identifying Shut-Off Valves A And B On Pressure Tester Kit
GWWN20-11041Courtesy of AUDI OF AMERICA, LLC
NOTE:

To measure the fuel delivery rate, an initial pressure must be created in the fuel line which the fuel pump must work against during measurement. Set the initial pressure using the :VAS6550/4  as follows:

-- Open the shut-off valves -A and B-.

CAUTION:

Risk of fuel leaking.

  • The shut-off valve -C- must be closed.
  • The lever is perpendicular to the flow direction.

-- Connect the Vehicle Diagnostic Tester.

-- Turn on the ignition and select the following menu items on the Vehicle Diagnostic Tester:

-- Push Start  : the fuel pump starts.

-- Turn the adjusting screw -1- on the :VAS6550/4  to create an initial pressure in the fuel system until the correct initial pressure value is reached.

Fig 3: Identifying Pressure Regulator Valve Adjusting Screw
GWWA20-11277Courtesy of AUDI OF AMERICA, LLC

-- Do not turn the adjusting screw -1- any farther.

-- Press the Stop  button.

-- Empty the measuring container.

-- To measure push the Start  button again and let the output diagnostic test mode run. Let it run for at least 30 seconds.

-- Then press the Stop  button.

-- Check the fuel delivery rate in the measuring container.

NOTE:

This output diagnostic test mode starts the fuel pump for 30 seconds. Then the fuel pump is switched off.

If the Minimum Delivery Rate is Attained:

If the Minimum Delivery Rate Is Not Obtained, It May Be Due to the Following Malfunctions:

NOTE:

To more accurately locate the malfunction, perform the "pressure test in the fuel supply line" described in the following.

- Pressure Test in the Fuel Supply Line

Fig 4: Identifying Shut-Off Valves A And B On Pressure Tester Kit
GWWN20-11041Courtesy of AUDI OF AMERICA, LLC

-- Switch on the :VAS6550  -1- by pressing the On/Off  button.

-- Open the shut-off valves -A and B-.

CAUTION:

Risk of fuel leaking.

  • The shut-off valve -C- must be closed.
  • The lever is perpendicular to the flow direction.

-- Press Start  on the Vehicle Diagnostic Tester display: the fuel pump starts running.

-- If the fuel flows without bubbles, close the shut-off valve -B- so that the fuel pressure increases.

-- Read the fuel pressure on the :VAS6550  :

If the Specified Value Is Obtained, Even Though the Fuel Delivery Rate Was Not OK:

If the Specified Value Is Not Attained:

- Checking Residual Pressure

-- Watch the pressure decrease on the :VAS6550  while checking the residual pressure and checking for leaks:

If the Residual Pressure Drops Below 3 bar (43 psi):