Home >> Audi >> 2017 >> A3 Premium, 2D Convertible >> Repair and Diagnosis >> Engine Mechanical >> Blowers, Superchargers & Turbochargers >> Fuel Supply -- (A3) >> 20 Fuel Supply >> Fuel System EVAP Leak Test >> EVAP SYSTEM LEAK TEST, VEHICLES WITH Leak Detection Pump -V144- (LDP) >> Fuel Cap, Testing

Fuel Cap, Testing

-- Connect fuel cap tester to hose.

-- Screw fuel cap tightly to cap receiver -arrow-.

GWWUS20-A163

-- Turn control valve to "Test".

-- Read flow meter on tester.

If no flow is indicated:

-- Proceed to Leak Detection Pump -V144-, TESTING FOR INTERNAL LEAKS .

If flow is indicated:

-- Replace fuel cap and re-test.

If new fuel cap shows no flow:

-- Repeat leak test, with new fuel cap installed, using Vehicle Diagnostic Tester in "Basic Settings" mode.

If Leak Test shows 'System OK":

-- Perform quality check and return vehicle to customer.