Battery -A- AND Auxiliary Battery -A1-, DISCONNECTING AND CONNECTING: Connecting
-- Disconnect the connector -2- from the Battery Monitoring Control Module -J367- /Battery Monitoring Control Module 2 -J934- -3-.
-- Connect the ground terminal to the battery negative pole "-" by hand and tighten the nut -1-.
-- Connect the electrical connector on the battery monitoring control module.
When the batteries are connected, the following steps must be performed:
- Activate the one-touch up/one-touch down power window regulators. Refer to the Owner's Manual.
- Check DTC memories of all control modules and erase "Undervoltage" DTC if necessary using the Vehicle Diagnostic Tester.
NOTE:
After connecting the power supply, the ABS warning lamp may only go out after the vehicle has been driven a few yards.