Home >> Audi >> 2016 >> S6 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 1116 (AIR CONDITIONING R1234yf (REFRIGERANT CIRCUIT) (COUPE)) >> 87 Air Conditioning >> Refrigerant Circuit >> System Overview - Refrigerant Circuit >> System Overview - Refrigerant Circuit With Electrically-Driven A/C Compressor (With Or Without Battery Cooling Module)

System Overview - Refrigerant Circuit With Electrically-Driven A/C Compressor (With Or Without Battery Cooling Module)

WARNING: This page does not describe the selected car, but rather 23 other vehicles, including the 2017 Audi S5, 2017 Audi A5 Quattro, 2016 Audi S5, 2016 Audi A5 Quattro, and 2015 Audi S5. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

The arrows indicate the refrigerant flow direction.

The following illustration shows a refrigerant circuit with an expansion valve and a second evaporator for cooling the battery and an inner heat exchanger as an example.

The Layout Of The Refrigerant Circuit Is Vehicle-Specific. Refer To REFRIGERANT CIRCUIT - 1 , REFRIGERANT CIRCUIT - 2 , REFRIGERANT CIRCUIT 1234yf - 2 , REFRIGERANT CIRCUIT GENERAL INFORMATION R134a , REFRIGERANT CIRCUIT R134a .

HD  = High Pressure Side

ND  = Low Pressure Side

Fig 1: Refrigerant Circuit With Electrically-Driven A/C Compressor (With Or Without Battery Cooling Module) Component Locations
GWWA87-11246Courtesy of AUDI OF AMERICA, LLC
  1. Electrically-Driven A/C Compressor
  2. Pressure Relief Valve
  3. Condenser
    • With receiver/dryer and dryer cartridge.
  4. Receiver/Dryer
    • Is a component of the condenser
  5. Refrigerant Pressure Sensor
  6. Service Connection - High Pressure Side
    • With closure cap.
  7. Refrigerant Line with Inner Heat Exchanger
  8. Refrigerant Shut-Off Valve
    • Different names. Refer to the appropiate service information HYBRID BATTERY REFRIGERANT SHUT-OFF VALVE 1 -N516-, REMOVING AND INSTALLING and EXPANSION VALVE WITH HYBRID BATTERY REFRIGERANT SHUT-OFF VALVE 2 -N517 .
    • Only on vehicles with a battery cooling module for the Hybrid Battery Unit -AX1-.
      NOTE:

      The Refrigerant Shut-Off Valve is for example activated, if the battery needs to be cooled and the vehicle interior is not already being cooled (open without activation).

  9. Expansion Valve
    • On the heater and A/C unit evaporator
  10. Front Evaporator
    • Heater and A/C unit evaporator
  11. Expansion Valve with Shut-Off Valve
    • Different names. Refer to the appropriate service information, HYBRID BATTERY REFRIGERANT SHUT-OFF VALVE 1 -N516-, REMOVING AND INSTALLING and EXPANSION VALVE WITH HYBRID BATTERY REFRIGERANT SHUT-OFF VALVE 2 -N517 .
    • On the evaporator in the battery cooling module
    • Only on vehicles with a battery cooling module for the Hybrid Battery Unit -AX1-.
      NOTE:

      The Expansion Valve with Shut-Off Valve is activated when it is necessary to cool the battery (closed without activation).

  12. Evaporator
    • Evaporator in the battery cooling module
    • Only on vehicles with a battery cooling module for the Hybrid Battery Unit -AX1-.
  13. Service Connection - Low Pressure Side
    • With closure cap