O-Ring Seals
These rings seal off the connection points between individual components of the refrigerant circuit.
Only O-rings that are resistant to refrigerant R134a and refrigerant oil must be installed. Make sure they are original replacement parts.
O-ring seals:
-- Always use only once.
-- Make sure diameters -a and b- are correct.
-- Coat with refrigerant oil before installing. Refer to REFRIGERANT CIRCUIT - CABRIOLET (1 OF 3) / REFRIGERANT CIRCUIT - CABRIOLET (2 Of 3) /REFRIGERANT CIRCUIT (R134a) - CABRIOLET (vehicle-specific repair information). (vehicle-specific repair information) and the parts information.
The color coding of refrigerant circuit O-rings with R134a has been discontinued. Black and colored O-rings are used. Refer to the parts information and O-RING SEALS [HVAC] / REFRIGERANT CIRCUIT - CABRIOLET (1 OF 3) / REFRIGERANT CIRCUIT - CABRIOLET (2 Of 3) /REFRIGERANT CIRCUIT (R134a) - CABRIOLET (vehicle-specific repair information). (vehicle-specific repair information).