LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 76 (SELF-LEVELING SUSPENSION (1 Of 2) (COUPE)) >> 43 Self-Leveling Suspension >> Dynamic Ride Control (DRC) >> Dynamic Ride Control (DRC), System Pressure Checking

Dynamic Ride Control (DRC), System Pressure Checking

WARNING: This page is about a different variant/trim than selected.

Special Tools And Workshop Equipment Required 

:VAS6209/2  Bleeding

Use only approved oil for the bleeding procedure.

NOTE:

The charging device :VAS6209/2  must always be bled the first time it is used.

If the charging device :VAS6209/2  still shows a residual pressure greater than 0.5 bar (7.2 psi) (for example, from a previous reading), bleeding must not be done.

-- To bleed pressure gauge -B- and line section -A-, install special tool as shown in illustration.

Fig 1: Bleeding Pressure Gauge And Line Section
GWWA43-10070Courtesy of AUDI OF AMERICA, LLC
NOTE:

The illustration shows bleeding process by extracting hydraulic fluid using a :VAS6213  .

-- Bleed process must be performed until air bubbles are no longer visible in hose -C-.

-- Disconnect hose -C and D- and perform system pressure check.

System Pressure Check Is Performed on Front Shock Absorber of Corresponding Dynamic Ride Control (DRC) Line.

Fig 2: Connecting V.A.S 6209/2 And Remove Dust Cap
GWWA43-10187Courtesy of AUDI OF AMERICA, LLC

-- Remove the cap from the extract/fill valve and connect the :VAS6209/2  .

-- Read the system pressure on the :VAS6209/2  .

Fig 3: Connecting V.A.S 6209/2 And Remove Dust Cap
GWWA43-10187Courtesy of AUDI OF AMERICA, LLC
NOTE:

The pressure on the :VAS6209/2  increases slowly and takes approximately two minutes. The DRC system pressure can only be read when the needle on the :VAS6209/2  has finally come to a stop.

-- Disconnect the :VAS6209/2  and install the dust cap.

Fig 4: Connecting V.A.S 6209/2 And Remove Dust Cap
GWWA43-10187Courtesy of AUDI OF AMERICA, LLC
NOTE:

A small oil leak at the connection that results from connecting or disconnecting the Dynamic Ride Control (DRC) System pressure tester for Audi RS4 :VAS6209/2  is not critical. Avoid repeating measurements because a small quantity of oil is removed from the system every time the DRC system pressure tester for Audi RS4 :VAS6209/2  is connected. Every connection results in a pressure decrease of approximately 0.3 bar (4.35 psi) from the previous reading. Multiple repeated measurements decrease system pressure belo w minimum pressure or failure.

-- If the pressure is not OK, determine the cause and service the system.

Dynamic Ride Control (DRC) System Pressure Values

Pressure values refer to reference temperature of 20 °C (68 °F).