Refrigerant Lines, Disconnecting And Connecting At Condenser, RS Models: Installing
Installation is done is reverse order, observe the following:
-- Replace the O-ring seals depending on the version. Refer to the Parts Information.
-- Check the alignment pin -A- (if equipped) for damage and make sure it fits correctly.
-- Check the guide ring -B- on the refrigerant line connection for damage.
-- Insert the O-ring -C- into the groove -arrow- in the refrigerant pipe connection -E and F-.
Coat the O-ring with refrigerant oil before installing. Refer to REFRIGERANT CIRCUIT SEALS .
Make sure the O-ring fits correctly inside the groove in the refrigerant pipe.
-- Tighten the bolts -D-.
- Tightening specification: 9 Nm
Following attachment, check routing of refrigerant lines on condenser. They must be inserted in holders provided and not make contact with other components.
-- Evacuate the refrigerant circuit and fill it. Refer to REFRIGERANT CIRCUIT
-- Operate the A/C system after filling the refrigerant circuit. Refer to A/C SYSTEM, STARTING OPERATION AFTER FILLING REFRIGERANT CIRCUIT .
-- Install the remaining removed components.
-- Turn on the ignition.
-- Check the DTC memory and erase any displayed entries using the Vehicle Diagnostic Tester in the "Guided Fault Finding" function.