LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 53 (Fuel Supply (Coupe)) >> 20 Fuel Supply >> Fuel Pump >> Transfer Fuel Pump -G6-, CHECKING >> Transfer Fuel Pump -G6-, CHECKING, A5/S5/RS5 THROUGH MY 2011, A4 THROUGH MY 2012 >> B - Pressure Test In The Fuel Supply Line

B - Pressure Test In The Fuel Supply Line

WARNING: This page is about a different variant/trim than selected.
Fig 1: Identifying Shut-Off Valves A And B On Pressure Tester Kit
GWWN20-11041Courtesy of AUDI OF AMERICA, LLC

-- Turn the Pressure Tester Kit:VAS6550  -1- on by pressing the On/Off  button.

-- Open the shut-off valves -A and B-.

CAUTION:

Risk of fuel leak.

  • The shut-off valve -C- must be closed.
  • The lever is perpendicular to the direction of flow.

-- Push the remote control switch: the fuel pump starts running.

-- If the fuel flows without bubbles, close the drain -B-, so that the fuel pressure increases.

-- Read the fuel pressure in the Pressure Tester Kit:VAS6550  :

If Specified Value Is Obtained, Although the Fuel Delivery Unit Is Not OK.

If the Specification Is Not Attained: