Fuel Tank Leak Detection Control Module With Integrated Fuel Tank Pressure Sensor, Removing And Installing: Removing
WARNING: This page is about a different variant/trim than selected.
-- Remove the Evaporative Emission (EVAP) canister. Refer to EVAP CANISTER, REMOVING AND INSTALLING .
-- Loosen the hose clamps to remove the ventilation hoses -3-.
-- Remove the bolts -1-.
-- Remove the Fuel Tank Leak Detection Control Module -J909- with integrated Fuel Tank Pressure Sensor -G400- -2- from the EVAP canister -arrow-.