LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 35 (Wires (Coupe)) >> 97 Wires >> ESD Work Surface :Vas6613 >> ESD Work Surface :Vas6613, Using

ESD Work Surface :Vas6613, Using

WARNING: This page is about a different variant/trim than selected.

-- Place The Electro-Static Discharge Mat -3- From :VAS6613  On A Clean, Dry Table.

GWWA96-10814Courtesy of AUDI OF AMERICA, LLC

-- Connect the Ground (GND) -2- to one of the buttons on the mat.

-- Connect the GND connector adapter -1- to the adapter connector on an outlet with contact protection or connect the alligator clip to a ground in the building or a water pipe.

-- Connect the wrist strap -4- to one of the buttons on the mat.

-- Attach the wrist strap directly to your wrist - never to your shirt sleeve or jacket sleeve.

CAUTION:

If working on especially sensitive electronic component and with the pad exposed, use only non-magnetic tools, for example, a :T10072  .