Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 28 (Air Conditioning (Refrigerant Circuit) (Coupe)) >> 87 Air Conditioning >> Refrigerant Circuit >> A/C Pressure/Temperature Sensor -G395-, CHECKING PRESSURE SIGNAL >> Test Sequence:

Test Sequence:

WARNING: This page is about a different variant/trim than selected.

-- Turn on the ignition.

-- Check the ground and positive connection to the terminal -A-.

-- Check the connection and the function of the A/C Pressure/Temperature Sensor -G395- using the Vehicle Diagnostic Tester in the "Guided Fault Finding" function.

NOTE:

The A/C compressor (A/C Compressor Regulator Valve -N280-) is not actuated when the connector -A- is disconnected.

The A/C Pressure/Temperature Sensor -G395- is an electronic control module over which exchanges information with the Vehicle Electrical System Control Module -J519- via a local Data Bus using the Vehicle Diagnostic Tester in the "Guided Fault Finding" function.