Lane Change Assistance, Preparing For Calibration
WARNING: This page is about a different variant/trim than selected.
- Calibration Tool - Spacing Laser -VAS6350/2-
- For distance measurement
- Usage information. Refer to the Operating Instructions.
- Calibration Unit -VAS6350A-
- Level
- On the Calibration Unit -VAS6350A-
- To check the horizontal position of the Calibration Unit -VAS6350A-
- Catch Bracket
- To mount the Calibration Tool - Spacing Laser -VAS6350/2- for the distance measurement
- Distance to the Calibration Tool - Wheel Center Mountings -VAS6350/1- on the rear wheels: dimension -a- = 1700 ± 2 mm
- Calibration Tool - Wheel Center Mountings -VAS6350/1-
- With wheel bolt adapter and measuring paddle
- Brand Emblem
- The laser point is aligned to the center of the brand emblem
- Calibration Tool - Lane Change Calibration Tool -VAS6350/4-
- Is moved from one side of the measuring field to the other during calibration
- When installed correctly, the vehicle electrical system voltage line must be connected at lower left of the calibration device (as seen in direction of travel)
- Measuring Scale
- For positioning the Calibration Tool - Lane Change Calibration Tool -VAS6350/4-
- Calibration Tool - Linear Laser -VAS6350/3-
- With "laser protective eyewear"
- On the Calibration Unit -VAS6350A-
- Turning on and off. Refer to the Operating Instructions.
- Plastic Foot
- Quantity: 3
- Can be adjusted when setting the horizontal position of the Calibration Unit -VAS6350A-