Severely Discharged Battery, Charging With Battery Charger :Vas5903: Procedure
-- Turn Off The Ignition And All Electrical Consumers And Remove The Ignition Key.
-- Connect The :VAS5903 To The Power Supply. The Last Selected Operation Mode Is Shown On The Display. Refer To BATTERY CHARGER .
-- Set The Battery Type With The INFO Button.
The Symbol -1- For "Service Charge Of Wet Batteries" Or The Symbol -2- For "Service Charge Of Gel/Absorbent Glass Mat (AGM) Batteries" Is Indicated In The Display.
-- Set The Battery Capacity (Ah) On The Battery -A- To Be Charged With The Corresponding ↑ Button Or ↓ Button.
-- Connect The Red Charge Terminal (+) To The Positive Terminal Of The Battery -A-.
On Vehicles With A Start/Stop Function And An Installed Battery Monitoring Control Module -J367-, The Black Charge Terminal (-) Must Be Connected To The Body Ground. The Start/Stop System Will Malfunction When It Is Connected To The Battery -A- Negative Terminal.
-- Connect The Black Charge Terminal (-) To The Negative Terminal Of The Battery -A- /Negative Connector.
-- Press The Start/Stop Button For About 5 Seconds. The Menu Selection "Charging Severely Discharged Batteries/Support Mode" Is Activated.
-- Press The Corresponding ↑ -button or ↓ Button To Adjust The Battery Voltage(6 V/12 V/24 V).
If No Button Is Touched Within Five Seconds, The :VAS5903 Will Return To The Main Menu (Operating Mode Selection).
-- Select The Battery Voltage By Pressing The START/STOP Button.
Then The Inquiry About The Correct Polarity Of The Charging Clamps Is Made.
-- Check Correct Polarity Connection Of Charger Clamps.
-- Confirm Charging Clamps Are Connected To Correct Poles Via START/STOP Button.
The :VAS5903 Starts To Charge The Severely Discharged Battery -A-.
Battery -A- Charging, Ending
-- Press the START/STOP -Button.
-- Remove The Charging Clamps From The Battery Terminals.
-- Disconnect The :VAS5903 From The Power.