Refresh Charging With Battery Charger :Vas5903: Notes
Special Tools And Workshop Equipment Required
- Battery Charger:VAS5900
Risk Of Injury. Follow All Warning Messages And Safety Precautions. Refer To WARNINGS AND SAFETY PRECAUTIONS .
Do Not Check Or Charge A Battery -A- When The Visual Indicator Has >>No Color Or Is Bright Yellow<<. Jump Starting Must Not Be Used!
There Is A Risk Of Explosion During Testing, Charging Or Jump Starting.
These Batteries -A- Must Be Replaced.
"Refresh Charging" Is Not Permitted For VW Vehicles, Because Voltage Surges Can Damage The On-Board Electronics.
The Battery -A- Must Always Be Disconnected From The Vehicle Electrical System When Using The "Refresh Charging" Mode.
Always Set The Mode That Corresponds To The Battery -A- During The Charging Process. Refer To The :VAS5903 Operating Instructions.
"Refresh Charging" Is Suitable For Wet Batteries, Which Must Be Filled With Distilled Water.
Do Not Use "Refresh Charging" Mode On Maintenance-Free Wet Batteries.
"Refresh Charging (Refr)" Mode Is Only Used On Batteries -A- That Are Possibly Defective (Sulfation). The Battery -A- Is Then Charged To The Maximum Specific Gravity Of The Electrolyte And The Plates Are Reactivated (Removal Of Sulfation Layer).
The Battery -A- Temperature Must Be At Least 10 °C.