LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 20 (Charging System (Battery, Starter, Generator) & Cruise Control (Battery & Charging) (Coupe)) >> 27 Starter, Generator And Cruise Control >> Battery, Charging >> Battery Charger :Vas5095A >> Battery, Charging With Battery Charger :Vas5095A >> Procedure

Battery, Charging With Battery Charger :Vas5095A: Procedure

WARNING: This page is about a different variant/trim than selected.

-- Turn Off The Ignition And All Electrical Consumers And Remove The Ignition Key.

-- Check The Battery Type Setting On The BATTERY TYPE  Switch. Refer To BATTERY CHARGER . The BATTERY TYPE  Switch Must Be Set To 2.4V/C (Volts/Cell)  .

-- Connect The Red Charge Terminal (+) To The Positive Terminal Of The Battery -A-.

NOTE:

On Vehicles With A Start/Stop Function And An Installed Battery Monitoring Control Module -J367-, The Black Charge Terminal (-) Must Be Connected To The Body Ground. The Start/Stop System Will Malfunction When It Is Connected To The Battery -A- Negative Terminal.

-- Connect The Black Charge Terminal (-) To The Negative Terminal Of The Battery -A- /Negative Connector.

-- Switch On The :VAS5095A  . Refer to BATTERY CHARGER .

Charge Current Displays. Refer To Figure -2- And -3- Light Up Yellow. The Battery -A- Is Partially Charged (Approximately 90 %) When Only The Yellow LED -3- is on.

If The Green LED. Refer To Figure -4- is also on, then the :VAS5095A  Has Switched To Maintenance Charging. The Battery -A- Is Charged.

-- Switch off the :VAS5095A  . Refer to BATTERY CHARGER .

-- Remove The Charging Clamps From The Battery Terminals.