LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 19 (Charging System (Battery, Starter, Generator) & Cruise Control (Start/Stop System) (Coupe)) >> 27 Battery, Starter, Generator, Cruise Control >> Battery >> Ground Cable With Battery Monitoring Control Module -J367-, Removing And Installing >> Removing

Ground Cable With Battery Monitoring Control Module -J367-, Removing And Installing: Removing

WARNING: This page is about a different variant/trim than selected.

-- Turn Off The Ignition And Remove The Key.

CAUTION:

TDI (SCR) Vehicles 

  • After The Ignition Is Switched Off, The Reducing Agent Goes From The Metering Line To The Reducing Agent Injector -N474- And Back Into The Reducing Agent Active Chamber.
  • Wait Until All The Reducing Agent Has Been Returned Before Working In This Area. This Could Take Up To 10 Minutes After Switching Off The Ignition.
  • Only After This Is Complete Can The Battery Be Disconnected. Again, This Could Take Up To 10 Minutes After Switching Off The Ignition.

COUPE: 

Fig 1: Battery Fluid Level
GWWA27-10139Courtesy of AUDI OF AMERICA, LLC

-- Lift The Luggage Compartment Floor And Engage It On The Body.

-- Remove The Nut -1- And Remove The Cover -2- For The Vehicle Tool Kit.

-- Remove The Tool Kit Mount.

SPORTBACK: 

Fig 2: Identifying Nut -1- And Tool Kit Cover -2-
GWWA27-10228Courtesy of AUDI OF AMERICA, LLC

-- Remove The Luggage Compartment Floor Panel Cover.

-- Remove The Nut -1- And The Tool Kit Mount -2-.

-- If Equipped, Remove The Subwoofer. Refer To SUBWOOFER -R211-, REMOVING AND INSTALLING .

Negative Terminal Cover - Version I: 

Fig 3: Loosen Nut Several Turns And Remove Ground Cable
GWWA27-10107Courtesy of AUDI OF AMERICA, LLC

-- Pull the cover -2- over the negative terminal upward slightly -arrow-.

-- Loosen the nut several turns and remove the battery ground cable terminal clamp -1- from the battery terminal.

-- Disconnect the connector -3-.

-- Remove the nut -6- and remove the ground cable -5- with the Battery Monitoring Control Module -J367- -item 4-.

Negative Terminal Cover - Version II: 

Fig 4: Opening Cover Over Battery Negative Terminal
GWWA27-10116Courtesy of AUDI OF AMERICA, LLC

-- Open the cover -2- over the battery negative terminal.

-- Loosen the nut several turns and remove the battery ground cable terminal clamp -1- from the battery terminal.

-- Disconnect the connector -3-.

-- Remove the nut -6- and remove the ground cable -5- with the Battery Monitoring Control Module -J367- -item 4-.