LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 999 (Brake System (Hydraulic Components - Service Information)) >> Hydraulic Components >> Vacuum System >> Vacuum System, Checking >> Leak Test

Leak Test

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S6, 2018 Audi A6 Quattro, 2018 Audi A6, 2017 Audi S6, and 2017 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

The average earth atmospheric air pressure at sea level (N. N.) is 1013 mbar (14.69 psi) and it decreases dramatically at higher altitudes (approximately 100 mbar (1.45 psi) every 1000 meters higher) Local and time fluctuations also influence the vacuum.

A cold engine, the A/C switched on as well as the engine simply idling can negatively influence the vacuum.

-- Check all the vacuum hoses beforehand for damage (for example, tears or damage caused by animals) and secure fit.

-- Connect the :VAS6721  . Refer to BRAKE BOOSTER TESTER, CONNECTING .

-- Open the shut-off valve -A-.

GWWN47-10210Courtesy of AUDI OF AMERICA, LLC

-- Close the shut-off valves -B and C-.

-- Start the warm (above 60 °C (140 °F)) engine and press the accelerator pedal one time quickly (engine speed higher than 2, 000 RPM).

Normally , the vacuum should be between 600 and 950 mbar (8.7 and 13.77 psi) (depending on the engine installed).

-- Open the shut-off valve -C- to evacuate the brake booster.

GWWN47-10213Courtesy of AUDI OF AMERICA, LLC

-- Turn off the engine.

-- Read the displayed measured value and write it down.

NOTE:

The vacuum will drop considerably within a few seconds if there are large leaks.

-- If the pressure drop is large, look for the area with the leak:

A - Testing the vacuum near the brake booster

GWWN47-10214Courtesy of AUDI OF AMERICA, LLC

-- Close the shut-off valve -A- after creating the vacuum to test the brake booster vacuum system.

B - Testing the vacuum near the check valve, vacuum hoses with connectors and vacuum pump/intake manifold

GWWN47-10210Courtesy of AUDI OF AMERICA, LLC

-- Close the shut-off valve -C- after creating the vacuum to check the vacuum system from the :VAS6721  up to the intake manifold or up to the vacuum pump.

Opening the shut-off valve -B- makes it easier to remove the hose connections and the adapter.