Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 961 (Turbocharger System (Service Information - CPNB)) >> 21 Turbocharger, Supercharger >> Turbocharger >> Turbocharger Vacuum Diaphragm, Adjusting >> Adjust The Turbine Switch-Over Vacuum Diaphragm >> Procedure

Adjust The Turbine Switch-Over Vacuum Diaphragm: Procedure

WARNING: This page is about a different car, the 2016 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

Follow all the rules of cleanliness..

-- Remove the engine cover. Refer to ENGINE COVER, REMOVING AND INSTALLING .

-- Loosen the clamp -3- and remove the air guide hose.

GWWA23-10531Courtesy of AUDI OF AMERICA, LLC
NOTE:

Ignore items -1 and 2-.

-- Remove the vacuum line to the vacuum diaphragm for the turbine switch-over on the Turbine Switch-Over Valve -N529- -arrow-.

GWWA21-10693Courtesy of AUDI OF AMERICA, LLC

-- Connect the :VAS6213  and :VAS6342  to the removed vacuum diaphragm and to connection "II" on the :VAG1397A  , as illustrated.

GWWA21-10664Courtesy of AUDI OF AMERICA, LLC

-- Connect the : VAS6342  .

-- Set the :VAS6213  slide ring -2- in the "vacuum" position.

-- Switch the :VAG1397A  and set the slide switch to position "II".

-- Select 02-Measured Values  in Guided Fault Finding 01 Engine Electronics  on the Vehicle Diagnostic Tester.

GWWA01-0123Courtesy of AUDI OF AMERICA, LLC

-- Select High Pressure Turbocharger Bypass Valve Turbine Input, Raw Voltage  from measured value list.

-- Operate the :VAS6213  until the :VAG1397A  shows the following value:

-- Read the voltage value on the Vehicle Diagnostic Tester.

-- Check the adjustment, to do this operate the :VAS6213  until the :VAS6213  pressure gauge displays the following values:

NOTE:

The :VAG1397A  cannot display values over 580 mbar (8.4 psi)

-- Read the voltage value on the Vehicle Diagnostic Tester.

If Specification Is Not Attained 

GWWA21-10597Courtesy of AUDI OF AMERICA, LLC

-- Remove the catalytic converter.

-- Reduce the vacuum via the :VAS6342  to approximately 100 mbar (1.4 psi).

NOTE:

The actuator rod -2- must be counterheld when loosening the lock nut -3-.

-- Open the lock nut -3- with the open-end wrench.

-- Unclip the lock washer -1- and remove the actuator rod from the adjusting lever.

-- Turn the upper part of the actuator rod -2- left or right on its own axis to extend or shorten it.

NOTE:

A half a turn of the actuator rod -2- equals a voltage change of 68 mV.

-- Push the actuator rod -2- on the adjusting lever.

GWWA21-10597Courtesy of AUDI OF AMERICA, LLC

-- Repeat the test with the :VAS6213  and the Vehicle Diagnostic Tester.

NOTE:

The actuator rod -2- must be counterheld when tightening the lock nut -3-.

-- If the specified value is now reached, install the lock washer -1- and tighten the lock nut -3-.

-- Check the adjustment again, to do this operate the :VAS6213  until the :VAS6213  pressure gauge displays the following values:

NOTE:

The :VAG1397A  cannot display values over 580 mbar (8.4 psi).

-- Read the voltage value on the Vehicle Diagnostic Tester.

If Specified Value Is Obtained

-- Install the catalytic converter.