LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 91 (HVAC System (Heater, Ventilator And A/C)) >> General Description >> Specification >> A/C System

A/C System

WARNING: This page is about a different car, the 2012 Subaru Forester. However, it is still accessible from the selected car via links, so may be relevant.
A/C SYSTEM SPECIFICATION CHART

Item Specifications
Type of air conditioner Reheat air-mix type
Cooling capacity 5.0 kW [at 480 m3 (16, 954 cu ft) /h] (4, 299 kcal/h, 17, 059 BTU/h)
Refrigerant HFC-134a(CH2 FCF3 ) [0.5±0.03 kg (1.1±0.07 lb)]
Compressor Type Rotary, constant volume (DVK-10R)
Discharge 105cc (6.41 cu in)/rev
Max. permissible speed 7, 700 rpm
Magnet clutch Type Dry, single-disc type
Power consumption Non-turbo model: 41.2 W
Turbo model: 38.8 W
Type of belt Non-turbo model: V-belt 6 PK
Turbo model: V-belt 4 PK
Pulley dia. (effective dia.) 100 mm (3.9 in)
Pulley ratio 1.32
Condenser Type Sub cool type
Core face area 0.188 m2 (2.002 sq ft)
Core thickness 16 mm (0.63 in)
Radiation area 4.5 m2 (48.44 sq ft)
Expansion valve Type Block
Evaporator Type Dual-tank
Dimensions (W x H x T) 290.1 x 172x39 mm (11.42 x 6.77 x 1.54 in)
Blower fan Fan type Sirocco fan
Outer diameter x width 150 x 75 mm (5.91 x 2.95 in)
Power consumption 260 W
Condenser fan (Sub fan) Motor type Magnet
Power consumption Non-turbo model: 90 W
Turbo model: 120 W
Fan outer diameter Non-turbo model: 300 mm (11.8 in)
Turbo model: 318.5 mm (12.5 in)
Radiator fan (Main fan) Motor type Magnet
Power consumption Non-turbo model: 90 W
Turbo model: 120 W
Fan outer diameter Non-turbo model: 300 mm (11.8 in)
Turbo model: 318.5 mm (12.5 in)
Idle speed MPFI model No load Non-turbo MT model: 650±100 rpm
Non-turbo AT model: 675±100 rpm
Turbo model: 700±100 rpm
A/C ON Non-turbo model: 850±100 rpm
Turbo model: 825±100 rpm
Triple switch (Pressure switch) Low-pressure switch operating pressure ON → OFF 177±25kPa (1.80±0.25 kgf/cm2 , 25.7±3.6 psi)
OFF → ON 206±30 kPa (2.10±0.31 kgf/cm2 , 29.9±4.3 psi)
High-pressure switch operating pressure ON → OFF 2, 940±200 kPa (29.98±2.04 kgf/cm2 , 426.3±29 psi)
OFF → ON 2, 350±200 kPa (24.00±2.04 kgf/cm2 , 340.7±29.0 psi)
Middle-pressure switch operating pressure ON → OFF 1, 470±120kPa (14.9911.22 kgf/cm2 , 213.15±17.4 psi)
OFF → ON 1, 770±100 kPa (18.05±1.02 kgf/cm2 , 256.65±14.5 psi)
Thermo-control amplifier working temperature