Charge Air System, Checking For Leaks, Vehicles With The Engine Code CGQB
Special tools and workshop equipment required
- Turbo System Tester Kit VAG1687 with Turbo System Tester Kit - Adapter 11 VAG1687/11 and Turbo System Tester Kit - Adapter 18 VAG168/18
Procedure
-- Remove the engine cover, refer to ENGINE COVER, REMOVING AND INSTALLING .
-- Open the clamps -arrows- and remove the air guide pipe -1-.
-- Remove the crankcase ventilation hose -1- from the support -2- by pressing the release buttons.
-- Remove the bolts -arrows- and then remove the support from the turbocharger.
-- Connect the Turbo System Tester Kit - Adapter 18-1 VAG168/18-1 with the Turbo System Tester Kit - Adapter 18-2 VAG168/18-2 to the turbocharger.
-- Loosen the hose clamp -arrow- and remove the air guide hose.
-- Connect the Turbo System Tester Kit - Adapter 11 VAG1687/11 on the air guide hose to the Throttle Valve Control Module -J338-.
-- Connect the hose -1- for the testing unit for turbo charger Turbo System Tester Kit VAG1687 to the adapter.
Prepare the Turbo System Tester Kit VAG1687 as follows:
-- Fully turn out the pressure regulator valve -2- to the closed position and close the valves -3- and -4-.
- The rotary knob must face upward so the pressure control valve -2- can be turned.
-- Connect the Turbo System Tester Kit VAG1687 to compressed air -1- with a commercially available adapter piece.
If there is water in the viewing glass, drain it through the drain plug -6-.
-- Open the valve -3-.
Damage could result if the pressure is set too high.
- Pressure must not exceed 0.5 bar!
-- Set the pressure to 0.5 bar using the pressure control valve -2-.
-- Open the valve -4- and wait until the test circuit is filled. Regulate the pressure to 0.5 bar again if necessary.
-- Listen, feel and use commercially available leak detection spray or the Ultrasonic Measuring Device VAG1842S to check the charge air system for leaks.
A small quantity of air dissipates via valves in engine. A pressure retention test is not possible for this reason.
For information on using the Ultrasonic Tester VAG1842S, refer to the instructions manual .
Release the pressure in the test circuit by pulling off the hose coupling before removing the adapter.
Assembling
Assemble in reverse order of disassembling. Note the following:
- Tightening specification Figure.
Replace the seal and O-rings.