Bleed The Fuel Supply Line To The Metering Pump
After working on the fuel delivery unit, bleed the fuel supply line for the metering pump on vehicles with a parking heater.
Special tools and workshop equipment required
- Suction Pump VAS5226
- Hand Vacuum Pump VAS6213
Procedure
- Parking heater switched off.
-- Remove the right center underbody panel, refer to OVERVIEW - UNDERBODY PANELS .
-- Remove the bolts -1 and 3-, nuts -4- and bracket -2-.
-- Press the release and disconnect the fuel line -1- to the auxiliary heater metering pump.
Ignore -2 and 3- and -arrow-.
-- Connect the Suction Pump VAS5226 to the compressed air.
-- Connect the Suction Pump VAS5226 with the adapter from the Hand Vacuum Pump VAS6213 to the fuel supply line -2- and bleed it by extracting briefly.
-- Install the fuel supply line to the metering pump -1-.
-- Switch the parking heater on and let it run approximately 10 minutes at full throttle.
-- Install the bracket, refer to Figure.
-- Install the right center underbody panel, refer to OVERVIEW - UNDERBODY PANELS .