Cooling Circuit Solenoid Valve -N492-, REMOVING AND INSTALLING
Special tools and workshop equipment required
- Hose Clamps - Up To 25mm 3094
- Hose Clip Pliers VAS6340
Removing
-- Drain the coolant, refer to COOLANT, DRAINING AND FILLING .
-- Remove the engine cover, refer to ENGINE COVER, REMOVING AND INSTALLING .
-- Disconnect the connector -1-.
-- Open the retainer -arrow- and move the Coolant Recirculation Pump -V50- to the side.
Ignore item -2-.
-- Disconnect the connector -5-.
-- Remove the nut -4- and the bolt -2- and separate the threaded connection -1-.
Place a clean cloth under the separating point to catch the escaping coolant.
Loosen the hose clamp -3- and remove the coolant hose.
Place a clean cloth under the separating point to catch the escaping coolant.
-- Remove the bolt -1-.
-- Loosen the bolt -4- approximately 2 turns but do not remove.
-- Loosen the clamp -2- and remove the coolant hose.
-- Lift the bracket for the pump unit slightly and remove the Cooling Circuit Solenoid Valve - N492-.
Ignore item -3-.
Install in reverse order of removal. Note the following:
Secure all hose connections with hose clamps of the same type as those equipped by the factory .
-- Install the engine cover, refer to ENGINE COVER, REMOVING AND INSTALLING .
Do not reuse used coolant.
-- Fill the coolant, refer to Filling - Hybrid Vehicles.
Tightening specifications