Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 627 (3.0L - Exhaust System & Emission Controls - Engine Code(S): CTUC & CTUD) >> 26 Exhaust System, Emission Controls >> Secondary Air Injection System >> Combination Valve, Checking For Function And Leaks

Combination Valve, Checking For Function And Leaks

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2017 Audi SQ5, 2017 Audi Q5, 2016 Audi SQ5, 2016 Audi Q5, and 2015 Audi SQ5. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Procedure

Fig 1: Identifying Strut Tower Brace, Bolts -1- And Nuts -2-
GWWA40-10131Courtesy of AUDI OF AMERICA, LLC

-- Remove the tower brace, refer to TOWER BRACE, REMOVING AND INSTALLING .

Right Secondary Air Injection Combination Valve:

Fig 2: Identifying Air Duct Pipe
GWWA24-10348Courtesy of AUDI OF AMERICA, LLC

-- Free up the fuel hose -1- and the EVAP canister hose -2- on the air duct pipe.

-- Remove the vacuum hose -3- from the air guide pipe connection.

-- Remove the air guide pipe by loosening the hose clamp -4- and opening the clips -arrows-.

Continued for Both Sides:

NOTE:

The illustration shows the left secondary air injection combination valve.

Ignore item -1-.

-- Remove the left and right bolts -3- for the secondary air injection hose.

-- Remove the vacuum line -2- from the secondary air injection combination valve.

Fig 3: Identifying Vacuum Line -2- And Secondary Air Injection (Air) Combination Valve
GWWA26-10424Courtesy of AUDI OF AMERICA, LLC

-- Connect the Hand Vacuum Pump VAS6213 to the vacuum connection -1- on the secondary air combination valve that will be tested.

Fig 4: Connecting Hand Vacuum Pump VAS 6213 To Vacuum Connection On Secondary Air Injection Combi-Valve
GWWA26-10338Courtesy of AUDI OF AMERICA, LLC

-- Connect a suitable assisting hose to the secondary air combination valve -2-.

-- Blow into the secondary air injection hose using light pressure (do not use compressed air).

-- Run the hand vacuum pump to generate a vacuum.

-- If the right Secondary Air Injection (AIR) combination valve does not react as described, replace it.

Assembling

Assembly is performed in the reverse order of disassembly, noting the following:

-- Install the tower brace, refer to TOWER BRACE, REMOVING AND INSTALLING .