Home >> Audi >> 2016 >> S5 Prestige, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 607 (Heating, Ventilation & Air Conditioning (1 Of 2) (As Of 06.2014)) >> 87 Air Conditioning >> Refrigerant Circuit >> Refrigerant Lines, Disconnecting And Connecting At Condenser >> Refrigerant Lines, Disconnecting And Connecting At Condenser >> Removing

Refrigerant Lines, Disconnecting And Connecting At Condenser: Removing

WARNING: This page does not describe the selected car, but rather 13 other vehicles, including the 2017 Audi SQ5, 2017 Audi Q5, 2016 Audi SQ5, 2016 Audi Q5, and 2015 Audi SQ5. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Identifying Bolt
GWWA87-10397Courtesy of AUDI OF AMERICA, LLC

-- Turn off the ignition.

-- Discharge the refrigerant circuit. Refer to USING SERVICE STATION (Refrigerant R134a, Servicing; Refrigerant Circuit, Using Service Station).

-- Remove the air guide for the left auxiliary radiator. .

-- Remove the bolt -B-.

-- Remove the refrigerant line -A- from the condenser.

-- Remove the bolt -1-.

Fig 2: Identifying Refrigerant Pipe Components
GWWA87-11477Courtesy of AUDI OF AMERICA, LLC

-- Remove the refrigerant pipe -2- from the condenser.

-- Seal the open lines and connections with clean plugs from the Engine Bung Set VAS6122.